FENCE PANEL CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws.

GATE CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws. Framed on each side of the gate; wider gates (over 6′ single gates, over 12′ double gates) include U-Frame. Welded at every picket-to-rail connection.

NOTE: never dig your post holes in advance of receiving your product(s).

ResidentialCommercialINDUSTRIAL
Powder Coat Colors7 colors to choose from
no cost difference
7 colors to choose from
no cost difference
7 colors to choose from
no cost difference
Vertical Pickets5/8″ sq. x .050″ (thick)
Pickets go through maximus rail
3/4″ sq. x .055″ (thick)
Pickets go through maximus rail
1″ sq. x .062″ (thick)
Pickets go through maximus rail
Picket Spacing
W/O Rings Styles 1, 2, 3, 4, 9 and 10
3 13/16 inches3 5/8 inches3 5/8 inches
Picket Spacing
with Rings Styles 1, 2, 3, 4, 9 and 10
3 3/4 inches3 3/4 inches3.750 inches
Picket Spacing
Styles 7 & 8 double pickets
1 5/8 inches1 1/2 inches1 1/2 inches
Horizontal Rails1″ x 1 1/8″
side wall = .082″ (thick)
top wall = .062″ (thick)
8 METAL INTERNAL RIBS
1 1/4″ x 1 3/8″
side wall = .088″ (thick)
top wall = .065″ (thick)
8 METAL INTERNAL RIBS
1 5/8″ x 1 5/8″
side wall = .100″ (thick)
top wall = .070″ (thick)
8 METAL INTERNAL RIBS
Fence Panel Heights3 feet, 3 1/2 feet, 4 feet,
4 1/2 feet, 5 feet, 6 feet
3 feet, 3 1/2 feet, 4 feet,
4 1/2 feet, 5 feet, 6 feet
4′, 5′, 6′, 7′, 8′
HEIGHTS
*Fence Panel WIDTHS6 feet wide only
TRIM TO FIT ON-SITE
6′ wide and *7.5′ wide
TRIM TO FIT ON-SITE
6.5′ wide and *8′ wide
TRIM TO FIT ON-SITE
Single Swing Gate WIDTHSOPENINGS up to 6 FEET wide
FRAMED & WELDED
OPENINGS up to 8 FEET wide
FRAMED & WELDED
OPENINGS up to 10 FEET wide
FRAMED & WELDED
Driveway / Estate Gate WIDTHSOPENINGS up to 12 FEET wide
FRAMED & WELDED
OPENINGS up to 16 FEET wide
FRAMED
& WELDED
OPENINGS up to 20 FEET wide
FRAMED & WELDED
Materials6005-T5 – 35,000 psi Aluminum Alloy6005-T5 – 35,000 psi Aluminum Alloy6005-T5 – 35,000 psi Aluminum Alloy
Material Origin100% Made in the USA100% Made in the USA100% Made in the USA
WarrantyLifetime Warranty on materials and paint finishLifetime Warranty on materials and paint finishLifetime Warranty on materials and paint finish

Style 10: 2-RAIL FLAT TOP fence panel is not available in 7.5′ wide or 8′ wide sections because this style has only 2 horizontal rails. Instead, use Flat Top, Flush Bottom Rail (Style 9) which is available in these wider sections.

NOTE: It’s ok to mix and match residential fencing with a commercial or industrial gate. Or, commercial fencing with an industrial gate. This happens often when a home or business needs a large driveway gate.

Ships to your home or business anywhere in the USA!

  Testing Competition
AAMA 2603
GREATFENCE.com
AAMA 2604-5
 


Pre-
treatment

Metal Preparation
and Pretreatment
Multi-Stage Cleaning and Pretreatment Multi-Stage Cleaning and Pretreatment
Pretreatment Type Chemical Conversion Coating Chrome or Non-Chrome Chemical
Conversion Coating
Pretreatment
Coating Weight
None Specified Chrome @ 30mg/ft² Minimum;
Non-Chrome per Supplier’s Specs
 

 

Paint Film

Dry Film
Thickness
0.8 mils min. 1.2 mils (for Multi-coat, 1.0 mil Topcoat
min & 0.3+/-0.1 mil Primer
Sealant
Compatibility
Meets AAMA 800 Meets AAMA 800
Specular Gloss +/-5 Units of Specification
(high = 80+, medium+20-79, low 19-)
+/-5 Units of Specification
(high = 80+, medium+20-79, low 19-)
Dry Film
Hardness
H Minium F Minimum
 

 

Adhesion

Dry Adhesion 0% Failure (No Loss) 0% Failure (No Loss)
Wet Adhesion 0% Failure (No Loss) 0% Failure (No Loss)
Boiling Water
Adhesion
None Specified 0% Failure (No Loss)
Impact
Resistance
No Removal of Film from Substrate No Removal of Film from Substrate
Abrasion
Resistance
None Specified Abrasion Coefficient Value = 20 Min
 



Chemical
Resistance

Muriatic Acid
Resistance
15 Minute Exposure: No Blistering or Visual Change for AAMA 2603, 2604, 2605
Mortar
Resistance
24 Hour Exposure: No Loss of Film Adhesion or Visual Change for AAMA 2603, 2604, 2605
Nitric Acid
Resistance
None Specified 30 Minute Exposure: 5 Delta E (Hunter)
Maximum Color Change
Detergent
Resistance
72 Hour Exposure: No Loss of Film Adhesion, No Blistering or
No Significant Visual Change for AAMA 2603, 2604, 2605
Window
Cleaner
Resistance
None Specified 24 Hour Exposure: No Blistering
or Visual Change



Corrosion
Resistance
Humidity Resistance 1500 Hours: No More than "Few" Blisters
Size 8, Figure #4 (ASTM D 714)
3000 Hours: No More than "Few" Blisters
Size 8, Figure #4 (ASTM D 714)

Salt Spray Resistance
1500 Hours of Salt Solution:
Minimum Rating of 7 on Scribe or Cut Edges;
Minimum Blister Rating of
8 in the Field (ASTM D 1654)
3000 Hours of Salt Solution:
Minimum Rating of 7 on Scribe or Cut Edges;
Minimum Blister Rating of
8 in the Field (ASTM D 1654)




Weathering
Resistance

Accelerated
Exposure
1000 Hours in Atlas Type "XW" Weatherometer:
No Adhesion Loss;
Slight Chalking or Color Change
 

None Specified


Outdoor
Exposure

1 Year South Florida: No Adhesion Loss;
Slight Chalking or Fading
5 Years South Florida: 5 Delta E
(Hunter) Maximum Color Change;
Chalking < 8 (ASTM D 4214);
Gloss Retention > 30%
Erosion Resistance < 10% Film Loss