FENCE PANEL CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws.
GATE CONSTRUCTION: pickets go through the rails and attached with 410 stainless steel, rust free screws. Framed on each side of the gate; wider gates (over 6′ single gates, over 12′ double gates) include U-Frame. Welded at every picket-to-rail connection.
NOTE: never dig your post holes in advance of receiving your product(s).
Residential | Commercial | INDUSTRIAL | |
Powder Coat Colors | 7 colors to choose from no cost difference | 7 colors to choose from no cost difference | 7 colors to choose from no cost difference |
Vertical Pickets | 5/8″ sq. x .050″ (thick) Pickets go through maximus rail | 3/4″ sq. x .055″ (thick) Pickets go through maximus rail | 1″ sq. x .062″ (thick) Pickets go through maximus rail |
Picket Spacing W/O Rings Styles 1, 2, 3, 4, 9 and 10 | 3 13/16 inches | 3 5/8 inches | 3 5/8 inches |
Picket Spacing with Rings Styles 1, 2, 3, 4, 9 and 10 | 3 3/4 inches | 3 3/4 inches | 3.750 inches |
Picket Spacing Styles 7 & 8 double pickets | 1 5/8 inches | 1 1/2 inches | 1 1/2 inches |
Horizontal Rails | 1″ x 1 1/8″ side wall = .082″ (thick) top wall = .062″ (thick) 8 METAL INTERNAL RIBS | 1 1/4″ x 1 3/8″ side wall = .088″ (thick) top wall = .065″ (thick) 8 METAL INTERNAL RIBS | 1 5/8″ x 1 5/8″ side wall = .100″ (thick) top wall = .070″ (thick) 8 METAL INTERNAL RIBS |
Fence Panel Heights | 3 feet, 3 1/2 feet, 4 feet, 4 1/2 feet, 5 feet, 6 feet | 3 feet, 3 1/2 feet, 4 feet, 4 1/2 feet, 5 feet, 6 feet | 4′, 5′, 6′, 7′, 8′ HEIGHTS |
*Fence Panel WIDTHS | 6 feet wide only TRIM TO FIT ON-SITE | 6′ wide and *7.5′ wide TRIM TO FIT ON-SITE | 6.5′ wide and *8′ wide TRIM TO FIT ON-SITE |
Single Swing Gate WIDTHS | OPENINGS up to 6 FEET wide FRAMED & WELDED | OPENINGS up to 8 FEET wide FRAMED & WELDED | OPENINGS up to 10 FEET wide FRAMED & WELDED |
Driveway / Estate Gate WIDTHS | OPENINGS up to 12 FEET wide FRAMED & WELDED | OPENINGS up to 16 FEET wide FRAMED & WELDED | OPENINGS up to 20 FEET wide FRAMED & WELDED |
Materials | 6005-T5 – 35,000 psi Aluminum Alloy | 6005-T5 – 35,000 psi Aluminum Alloy | 6005-T5 – 35,000 psi Aluminum Alloy |
Material Origin | 100% Made in the USA | 100% Made in the USA | 100% Made in the USA |
Warranty | Lifetime Warranty on materials and paint finish | Lifetime Warranty on materials and paint finish | Lifetime Warranty on materials and paint finish |
Style 10: 2-RAIL FLAT TOP fence panel is not available in 7.5′ wide or 8′ wide sections because this style has only 2 horizontal rails. Instead, use Flat Top, Flush Bottom Rail (Style 9) which is available in these wider sections.
NOTE: It’s ok to mix and match residential fencing with a commercial or industrial gate. Or, commercial fencing with an industrial gate. This happens often when a home or business needs a large driveway gate.

Ships to your home or business anywhere in the USA!
Testing |
Competition AAMA 2603 |
GREATFENCE.com AAMA 2604-5 |
|
|
Metal Preparation and Pretreatment |
Multi-Stage Cleaning and Pretreatment | Multi-Stage Cleaning and Pretreatment |
Pretreatment Type | Chemical Conversion Coating |
Chrome or Non-Chrome
Chemical Conversion Coating |
|
Pretreatment Coating Weight |
None Specified |
Chrome @ 30mg/ft² Minimum; Non-Chrome per Supplier’s Specs |
|
Paint Film |
Dry Film Thickness |
0.8 mils min. |
1.2 mils (for Multi-coat,
1.0 mil Topcoat min & 0.3+/-0.1 mil Primer |
Sealant Compatibility |
Meets AAMA 800 | Meets AAMA 800 | |
Specular Gloss |
+/-5 Units of Specification (high = 80+, medium+20-79, low 19-) |
+/-5 Units of Specification (high = 80+, medium+20-79, low 19-) |
|
Dry Film Hardness |
H Minium | F Minimum | |
Adhesion |
Dry Adhesion | 0% Failure (No Loss) | 0% Failure (No Loss) |
Wet Adhesion | 0% Failure (No Loss) | 0% Failure (No Loss) | |
Boiling Water Adhesion |
None Specified | 0% Failure (No Loss) | |
Impact Resistance |
No Removal of Film from Substrate | No Removal of Film from Substrate | |
Abrasion Resistance |
None Specified | Abrasion Coefficient Value = 20 Min | |
|
Muriatic Acid Resistance |
15 Minute Exposure: No Blistering or Visual Change for AAMA 2603, 2604, 2605 | |
Mortar Resistance |
24 Hour Exposure: No Loss of Film Adhesion or Visual Change for AAMA 2603, 2604, 2605 | ||
Nitric Acid Resistance |
None Specified |
30 Minute Exposure: 5 Delta
E (Hunter) Maximum Color Change |
|
Detergent Resistance |
72 Hour Exposure: No Loss
of Film Adhesion, No Blistering or No Significant Visual Change for AAMA 2603, 2604, 2605 |
||
Window Cleaner Resistance |
None Specified |
24 Hour Exposure: No
Blistering or Visual Change |
|
Corrosion Resistance |
Humidity Resistance |
1500 Hours: No More than
"Few" Blisters Size 8, Figure #4 (ASTM D 714) |
3000 Hours: No More than
"Few" Blisters Size 8, Figure #4 (ASTM D 714) |
Salt Spray Resistance |
1500 Hours of Salt
Solution: Minimum Rating of 7 on Scribe or Cut Edges; Minimum Blister Rating of 8 in the Field (ASTM D 1654) |
3000 Hours of Salt
Solution: Minimum Rating of 7 on Scribe or Cut Edges; Minimum Blister Rating of 8 in the Field (ASTM D 1654) |
|
Weathering Resistance |
Accelerated Exposure |
1000 Hours in Atlas Type "XW"
Weatherometer: No Adhesion Loss; Slight Chalking or Color Change |
None Specified |
Outdoor Exposure |
1 Year South Florida: No Adhesion Loss; Slight Chalking or Fading |
5 Years South Florida: 5
Delta E (Hunter) Maximum Color Change; Chalking < 8 (ASTM D 4214); Gloss Retention > 30% Erosion Resistance < 10% Film Loss |